Two hole nylon  waterproof cable gland

Two hole nylon waterproof cable gland

• Materials: Nylon + EPDM rubber

• Waterproof: IP68

• Temperature:-40°~105°,Short-term 120° 

• fire prevention:UL94V-2, Customizable V0

• performance:ROHS20, EU CE, IP68

TWO HOLE CABLE GLAND SIZE

Product model Thread size Cable range Thread length Wrench Size
PN. Metric φ mm GL mm nut/cap mm
MG12A-H2-03 M12×1.5 1.5~3 8.5 18/19
MG16AS-H2-03 M16×1.5 1.5~3 10 22/19
MG16A-H2-04 M16×1.5 2~4 15 22/22
MG20A-H2-06 M20×1.5 3~6 15 27/27
MG20A-H2-05 M20×1.5 2~5 15 27/27
MG20A-H2-04 M20×1.5 2~4 15 27/27
MG20A-H2-03 M20×1.5 1.5~3 15 27/27
MG20AS-H2-05 M20×1.5 2~5 10 27/24
MG22A-H2-06 M22×1.5 3~6 10 29/27
MG22A-H2-05 M22×1.5 2~5 10 29/27
MG22A-H2-04 M22×1.5 2~4 10 29/27
MG22A-H2-03 M22×1.5 1.5~3 10 29/27
MG25A-H2-08 M25×1.5 5~8 15 33/33
MG25A-H2-06 M25×1.5 3~6 15 33/33
MG25A-H2-05 M25×1.5 2~5 15 33/33
MG32A-H2-10 M32×1.5 6~10 15 41/41
MG40A-H2-13 M40×1.5 9~13 20 50/50
MG50A-H2-15 M50×1.5 11~15 22 62/62
MG63A-H2-17 M63×1.5 14~17 25 75/78
PG7A-H2-03 PG7 1.5~3 8.5 17/19
PG9A-H2-03 PG9 1.5~3 8.5 22/19
PG11A-H2-04 PG11 2~4 10 22/22
PG13.5A-H2-05 PG13.5 2~5 10 27/24
PG16A-H2-06 PG16 3~6 11 30/27
PG16AH2-05 PG16 2~5 11 30/27
PG16A-H2-04 PG16 2~4 11 30/27
PG16A-H2-03 PG16 1.5~3 11 30/27
PG21A-H2-08 PG21 5~8 12 36/33
PG21A-H2-06 PG21 3~6 12 36/33
PG21A-H2-05 PG21 2~5 12 36/33
PG29A-H2-10 PG29 6~10 12 46/41
PG36A-H2-13 PG36 9~13 15 57/50
PG42A-H2-15 PG42 11~15 15.5 64/62
PG48A-H2-17 PG48 14~17 16 75/78
G1/4A-H2-03 G1/4 1.5~3 8.5 19/19
G3/8A-H2-04 G3/8 2~4 15 22/22
G1/2A-H2-06 G1/2 3~6 15 30/27
G1/2A-H2-05 G1/2 2~5 10 27/24
G3/4A-H2-08 G3/4 5~8 15 33/33
G3/4A-H2-06 G3/4 3~6 15 33/33
G3/4A-H2-05 G3/4 2~5 15 33/33
G1-1/4A-H2-13 G1-1/4 9~13 16 51/50
G1-1/2A-H2-15 G1-1/2 11~15 22 62/62
G2A-H2-17 G2 14~17 25 75/75

Recommended Products

Recommended News

NEC Requirement for DC Arc Fault Protection on Rooftop Solar

What Is the NEC Requirement for DC Arc Fault Protection on Rooftop Solar?

The National Electrical Code (NEC) has specific requirements for DC arc-fault protection on rooftop photovoltaic (PV) systems. These requirements, codified in NEC Article 690.11, are designed
Rapid Shutdown Device

Why Is My Rapid Shutdown Device Not Turning Back On After a Test?

In photovoltaic systems, the failure of a rapid shutdown device (RSD) to restart after a test is a common but frustrating problem. Many technicians, after completing a shutdown test, find the

GET A QUOTE

GET IN TOUCH NOW
Captcha Code
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All