Main function

 

With overload delay protection, short circuit instantaneous protection, used to distribute electric energy, protect circuit and the power supply equipment from the danger of overload,short circuit etc.

 

 

Application

 

Suitable for circuits below 1500VDC
cabinet/combiner box/photovoltaic system

 

 

Model and significance

 

SM8 - 630 H / PV DC1500V 630
Product code
MCCB
  case grade:630 Breaking capacity:
H(15kA)
  Pv code:
DC dedicated
Rated working voltage:
DC1500V
Rated working current:
100 / 125 / 160 / 200 / 225 / 250 / 400 / 500 / 630A

 

 

Auxiliary contact specifications

 

AX - 630PV
Attachment code   Case grade code

 

 

Alarm contact specifications:L630PV

 

AX - 630PV
Attachment code   Case grade code

 

 

Shunt release specification

 

SHT 630HPV R AC230V
Attachment code Case grade code Accessory installation location:
installation right
Control voltage:
DC24V / AC230V / AC400V

 

 

Advantages and certification

 

Labyrinth arc extinguisher Built-in double row moving contacts Easy to install accessories
Prevent the spread of arcs in current surges lncrease the arc voltage Realize multiple protections
(excitation, auxiliary, alarm etc.)
Base is made of DMC material 630A frame size with arc shield lnternational Certification
v0 flame retardant Effectively isolate the external arc TUV、CE、CB

 

 

The role of installation accessories

 

 

 

Specifications

 

Model SM8-250HPV /31500V SM8-630HPV / 4 1500V
Product name PV DC MCCB PV DC MCCB
Rated operational voltage DC1500V DC1500V
Nominal insulation voltage 1500V 1500V
Rated impulse voltage 12kV 12kV
Pole 3 4
Type of release Thermal magnetic type (thermal magnetic not adjustable)
Executive standard GB14048.2, IEC / EN 60947-2
Use category A (PV-1)
Case grade current 250A 630A
Rated operational current 100/125/160/200/225/250A 400/500/630A
Breaking capacity H
Rated ultimate short-circuit breaking capacity Ue1500v 15kA Ue1500v 30kA
Ue1500v 30kA
Operation breaking capacity Ue1500v 15kA Ue1500v 30kA
Ue1500v 30kA
Long delay protection 1 In
lnstantaneous protection 6ln ( Min1000A )
Mechanical life 10000times
Electrical life 2000times
Dimensions 135×200 x 86mm Type H:310×240×155mm
Type G:350×240×155mm
Installation method Fixed Fixed
Protection level Wiring port: lP20 / all sides: IP40  
Relative humidity +50°C not more than 95%  
Whether there are wiring polarity requirements No
Pollution level Level 3
Operating temperature -40°℃ -+75°℃
Operation instructions With ON / OFF indication
Whether the release is adjustable No
Electrical accessories Optional: shunt/auxiliary/alarm
(note: only one set can be installed on the left and right sides of auxiliary, alarm and shunt)
2P only on the left
lsolation function yes

 

 

Dimensions and wiring

 

 

 

Recommended Products

Recommended News

SOLAR ENERGY EXPO 2024: Aligning with global Renewable Energy Sources

Mazowieckie, Poland -January 18, 2024 Suntree, a leading innovator in the renewable energy sector, expresses immense gratitude to everyone involved in the recently concluded SOLAR ENERGY EXPO 2024 held at ...
Successful Conclusion of the 2024 Suntree International Strategic Conference

Successful Conclusion of the 2024 Suntree International Strategic Conference

The 2024 Suntree International Strategy Conference recently concluded at the Jiangnan Intercontinental Hotel , marking two days of intense discussions and strategic planning for Suntree’s international dev...

GET A QUOTE

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All